banner

Master Alarm Panel

Delivery term:The date of payment from buyers deliver within days
  • Price:

    Negotiable

  • minimum:

  • Total supply:

  • Delivery term:

    The date of payment from buyers deliver within days

  • seat:

    Zhejiang

  • Validity to:

    Long-term effective

  • Last update:

    2020-09-29 08:54

  • Browse the number:

    175

Send an inquiries
Company Profile
Hangzhou Lihua Science&Technology Co., Ltd
By certification [File Integrity]
Contact:

hzlihua(Mr.)  

Email:

Telephone:

Phone:

Area:

Zhejiang

Address:

31-2 Jiuhuan Road, Hangzhou, P.R.C

Website: http://www.lihuast.com/ http://hzlihua.dgbcsj.com/
Product details

In the medical gas system, a gas monitoring alarm system is generally installed. Their function is to provide the equipment management personnel and medical staff with the status parameters of the medical gas system in real time. Once the parameters exceed the normal range, they will send out sound and light alarm signals to give an alarm.

Oxygen, vacuum suction, and compressed air are the three most important medical gases, which should be installed in general hospitals. The gas source and pipeline supply system should be safe and reliable. The oxygen, vacuum suction, and compressed air pipelines should be divided into two supply lines. The oxygen, vacuum, and compressed air pipelines for the clean operation department must be supplied separately. In the ward building, each floor nurse station is equipped with oxygen, vacuum, compressed air overpressure and underpressure alarm devices.


Technical Index

1. Pressure range: positive pressure: 0KPa-999KPa (special requirements can be increased).

Negative pressure: 0KPa--99KP

2. Resolution: 1KPa

3. Accuracy: ±1.5%

4. Output signal: standard modbus protocol signal

5. Alarm default value:

Gas

Upper limit alarm

Upper limit warning

Lower limit warning

Lower limit alarm

Positive pressure

500KPa

450KPa

350KPa

300KPa

Negative pressure

-90KPa

-80KPa

-40KPa

-30KPa


6. Dimensions:

Gas type

Dimensions

Dimension of wall hole

1 type of gas pressure

204×40×210

186×50×192

2 types of gas pressure

286×40×210

268×50×192

3 types of gas pressure

368×40×210

350×50×192

4 types of gas pressure

458×40×210

440×50×192

5 types of gas pressure

540×40×210

520×50×192

6 types of gas pressure

614×40×210

584×50×192

Special requirements can be increased


7. Power supply: AC220V 50Hz (can be customized according to customer requirements)


Function of Master Alarm Panel

1. The MCU of the controller adopts a high-speed single-chip microcomputer, which has fast calculation speed, high precision and strong reliability. It can quickly process system tasks and ensure the reliability of system operation.

2. This regional gas pressure monitoring alarm is suitable for monitoring the gas supply pressure status of hospital floors, nurse stations, operating rooms, ICU or laboratory gas pipelines, special gas cylinders, bus bars, gas valve boxes, etc., through digital tubes The display shows the pressure of the monitored gas in real time. The alarm point can be set according to the usage requirements of each parameter, and over-limit alarm is realized to ensure the normal air supply pressure in the area.

3. This regional gas pressure alarm is equipped with RS-485 communication interface, which can realize the networking with the main alarm box and the system host through the network.

http://www.lihuast.com/